NetWay8M/NetWay16M - 3 -
Fig. 1
1a OUT 1-8 (NetWay8M), OUT 1-16 (NetWay16M): Structured cable to PoE compliant cameras/edge devices.
1b IN 1-8 (NetWay8M), IN 1-16 (NetWay16M): Structured cable to ethernet switch or video server.
1c LED(s) 1-8 (NetWay8M), 1-16 (NetWay16M): Port status LEDs.
1d Reset: Restores unit to factory settings.
1e +---,PoEShutdown:Lowvoltagetriggerinput(see Technical Specifications pg. 5).
1f Ethernet: LAN or laptop connection enables NetWayM programming and status monitoring.
1g Illuminated master power disconnect circuit breaker (switch):
• OFFpositionCircuitbreakertrippedSwitchnotilluminated.
• RESET(ON)positionSwitchilluminated.
1h IEC320Connector:115VAC60Hz(groundedlinecordincluded).
AC POWER
NetWay8M & NetWay16M - Rear Panel
NetWay8M - Front Panel
NetWay16M - Front Panel
+ PoE --
SHUTDOWN
+ PoE --
SHUTDOWN
1a
1b
1c
1d
1e 1f
1g
1h
Note: All interconnected devices must be UL Listed.
7. Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 1g, pg. 3).
8. Port status LEDs on the NetWayM will initialize when PoE devices are connected as follows:
- LED will illuminate when devices are IEEE 802.3af compliant.
- LED will blink once and illuminate when devices are IEEE802.3at compliant (PoE Plus).
9. To utilize the PoE shutdown feature it is necessary to do the following:
a. Connect a device that will provide a low voltage trigger input (see Technical Specifications pg. 5) to terminals
marked[+---,PoEShutdown]ontheNetWayM(Fig. 1e, pg. 2). When voltage is applied, the PoE shutdown
  enabledPoEport(s)willdroptozerovolts.Removingthelowvoltagetriggerinputatthe[+---,PoEshutdown]
terminals will allow the PoE port(s) to operate normally and supply power to PoE compliant devices. Power will
reset in approximately 4 seconds. Although there is no output voltage to power PoE devices during shutdown, data
signals may still be present on the data pair lines of the structured cable.
b. Individual ports must be programmed utilizing the user interface (see User Interface and Programming, pgs. 6 & 7).
Port Status and LED Flash Codes:
Port Status Flash Codes Description
All Ports Off Sequential LED Port Scan No devices connected
Port Off OFF LED OFF
Port On ON LED ON
Class 4 detection Port Blinks 2 times Enables power to PoE devices.
Non-compliant Device 2Hz Will prevent port from turning on.
Port Overload Fault 5Hz Will prevent port from turning on.
4 Port Overload Grouped 5Hz
4 LEDs
Will prevent ports from turning on.
8 Port Overload Grouped 5Hz
LEDs 1-8 Power Supply Overload for ports 1-8.
LEDs 9-16 Power Supply Overload for ports 9-16.