ALTV2432 Series
CCTV Power Supplies
Installation Guide
Models Include:
ALTV2432 ALTV2432CB
- 24VAC @ 8 amp (200VA) - 24VAC @ 8 amp (200VA)
or 28VAC @ 7 amp. or 28VAC @ 7 amp.
- Thirty-two (32) Fuse Protected Outputs. - Thirty-two (32) PTC Protected Outputs.
ALTV2432350 ALTV2432350CB
- 24VAC @ 14 amp (350VA) - 24VAC @ 14 amp (350VA)
or 28VAC @ 12.5 amp (350VA). or 28VAC @ 12.5 amp (350VA).
- Thirty-two (32) Fuse Protected Outputs. - Thirty-two (32) PTC Protected Outputs.
ALTV2432600 ALTV2432600CB
- 24VAC @ 28 amp (700VA) - 24VAC @ 28 amp (700VA)
or 28VAC @ 25 amp (700VA). or 28VAC @ 25 amp (700VA).
- Thirty-two (32) Fuse Protected Outputs. - Thirty-two (32) PTC Protected Outputs.
Rev. 021704
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - ALTV2432 Series

ALTV2432 Series CCTV Power SuppliesInstallation GuideModels Include:• ALTV2432 • ALTV2432CB- 24VAC @ 8 amp (200VA) - 24VAC @ 8 amp (200VA)or 28VAC @

Page 2 - Enclosure Dimensions:

Overview:These Altronix CCTV Power Supplies provide 24VAC/28VAC distributed via thirty-two (32) fuse or PTC protected outputs for powering CCTV Camera

Page 3 - Terminal Identification:

- 3 -7. Turn main switch on unit to the ON (RESET) position (Figs. 1-3, pgs. 4-6).8.Green LED(s) will illuminate when unit is powered.9.Upon completio

Page 4 - Terminal Blocks for Fig. 1

- 4 -Fig. 1ALTV2432 • ALTV2432CBWhiteLeadPowerSwitchBlackLead115VAC input,50/60 Hz.Used on PTC Models(example: ALTV2432CB)GreenLead(Ground)Connected t

Page 5 - ALTV2432350 • ALTV2432350CB

- 5 -Fig. 2ALTV2432350 • ALTV2432350CBBlack Lead White Lead 115VAC input50/60 Hz,Used on PTC Models(example: ALTV2432350CB)XFMR*GreenLead(Ground)Conn

Page 6 - Terminal Blocks for Fig. 3

- 6 -WhiteLeadPowerSwitchXFMR*BlackLead115VAC input,50/60 Hz.Used on PTC Models(example: ALTV2432600CB)XFMR*GreenLead(Ground)Connected to Door3.5A 2

Page 7 - TOP ONLY

- 7 -000.81"01.1875"1.1875"3.25"3.25"0 1.1875" 3.25".75" 1.5" 6.25" 11"1.4"6.5"5.5&qu

Page 8

- 8 -Altronix Corp.140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056web site: www.altronix.com, e-mail: [email protected]