ALTV244UL Series
CCTV Power Supplies
Installation Guide
Models Include:
ALTV244UL ALTV244ULCB
- 24VAC @ 3.5 amp (85VA) - 24VAC @ 3.5 amp (85VA)
or 28VAC @ 3 amp (85VA). or 28VAC @ 3 amp (85VA).
- Four (4) Fuse Protected Outputs. - Four (4) PTC Protected Outputs.
ALTV244ULX
- 24VAC @ 3.5 amp (85VA)
or 28VAC @ 3 amp (85VA).
- Four (4) Fuse Protected Outputs.
ALTV244175UL ALTV244175ULCB
- 24VAC @ 7 amp (175VA) - 24VAC @ 7 amp (175VA)
or 28VAC @ 6.25 amp (175VA). or 28VAC @ 6.25 amp (175VA).
- Four (4) Fuse Protected Outputs. - Four (4) PTC Protected Outputs.
Re
v
.
040406X
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - ALTV244UL Series

ALTV244UL Series CCTV Power SuppliesInstallation GuideModels Include:• ALTV244UL • ALTV244ULCB- 24VAC @ 3.5 amp (85VA) - 24VAC @ 3.5 amp (85VA)or 28VA

Page 2 - Enclosure Dimensions:

Overview:The following Altronix CCTV Power Supplies provide 24VAC or 28VAC distributed via four (4) fuse or PTC protectedoutputs for powering CCTV Cam

Page 3

- 3 -3. All units are factory set for 24VAC operation. For 28VAC operation adjust unit prior to applying power as follows: Remove wires marked [24V]

Page 4 - MAIN FUSE

- 4 -Fig. 1 ALTV244UL1P 1N 2P 2N 3P 3N 4P 4NLED3.5A 250V3.5A 250V3.5A 250VXFMRWhiteLead BlackLead BlackLead non-powerlimitednon-powerlimited115VAC Inp

Page 5 - ALTV244ULX

- 5 -Fig. 3 ALTV244ULX1P 1N 2P 2N 3P 3N 4P 4NLED3.5A 250V3.5A 250V3.5A 250VONOFFSW1INPUTN P SMAIN FUSEDoor115VAC50/60Hz Input,.9 ampGreenLead(ground)B

Page 6 - Illuminated Power Disconnect

- 6 -XFMRBlackLeadnon-powerlimited115VAC Input50/60 Hz.GreenLead(Ground)WhiteLeadIlluminated Power Disconnect Circuit Breaker with manual resetClass 1

Page 7

- 7 -3.625”1.25”6.05”7.25”6.05”8.125”1.00”0.60”1.25”2.00”2.00”0.60”1.125”3.50”1.00”0.60”1.25”3.50”1.125”0.60”5.25” 1.00”1.00”1.00”3.50”Enclosure Dimen

Page 8 - Enclosure Dimensions for:

- 8 -Altronix Corp.140 58th Street, Brooklyn, NewYork 11220 USA, 718-567-8181, fax: 718-567-9056web site: www.altronix.com, e-mail: [email protected],