Altronix new Maximal33RD rack mount access power controller distributes and switches power to access control
systems and accessories. It converts a 115VAC 50/60Hz input into sixteen (16) independently
controlled 12VDC and/or 24VDC PTC protected outputs. Outputs are activated by an normally open (NO)
or normally closed (NC) dry trigger input from an Access Control System,
Card Reader, Keypad, Push Button, PIR, etc. This unit will route
power to a variety of access control hardware devices including:
Mag Locks, Electric Strikes, Magnetic Door Holders, etc.
Outputs will operate in both Fail-Safe and/or Fail-Secure
modes. The FACP Interface enables Emergency Egress, Alarm
Monitoring, or may be used to trigger other auxiliary devices.
The fire alarm disconnect feature is individually selectable
for any or all of the outputs.
Input:
• 115VAC60Hz.,3.8amp.
• Normallyclosed[NC]ornormallyopen[NO]
dry contact inputs (switch selectable).
Outputs:
• 12VDCor24VDC@12amptotaloutputcurrent.
Powersupply1/(8)outputs:
12VDC@6ampor24VDC@6amp
Powersupply2/(8)outputs:
12VDC@6ampor24VDC@6amp
• Sixteen(16)PTCprotectedoutputs.
• MaximumcurrentperACM8R-Moutputis2amp.
• IndividuallyselectableMagLock/Strike(Fail-Safe,
Fail-Secure) solid state fuse protected outputs.
• Thermalandshortcircuitprotectionwithautoreset.
Fire Alarm Interface:
• LatchingorNon-Latchingfirealarmresetswitch
individually selectable for each output.
• RemoteresetcapabilityforlatchingFireAlarm
Interface mode.
• FireAlarmdisconnectinputoptions:
a) Normallyopen[NO]ornormallyclosed[NC]
dry contact input.
b) Polarity reversal input from FACP signaling
circuit.
Visual Indicators:
• IndividualOutputStatusLEDslocatedonthe
front panel.
Battery Backup:
• Built-inchargerforsealedleadacidorgeltype
batteries (if batteries are required install
separate enclosure).
• Maximumchargecurrent.7amp.
• Automaticswitchovertostand-bybattery
when AC fails.
• Zerovoltagedropwhenunitswitchesovertobattery
backup (AC failure condition).
Supervision:
• ACfailsupervision(form“C”contact).
• Lowbatteryandbatterypresencesupervision
(form“C”contact).
Additional Features:
• Removableterminalblockswithlockingscrewflange.
• 3-wirelinecord.
• Illuminatedmasterpowerdisconnectcircuitbreaker
with manual reset.
Rack Dimensions:
3.25”Hx19.125”Wx8.5”D
Shipping Weight (approximate):
- Maximal33RD: 14.3 lbs.
Maximal33RD
Rack Mount Access Power Controller
Rev.DSMaximal33RD-A19K
Overview
Specifications
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Maximal33RD

Altronix new Maximal33RD rack mount access power controller distributes and switches power to access control systems and accessories. It converts a 1

Page 2 - 3.25”Hx19.125”Wx8.5”D

Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.comFRONT3.125" 8.5" .75" 19.125" 17.

Commentaires sur ces manuels

Pas de commentaire