Rev. 042209AL602ULADANAC Power ExtenderInstallation Guide(see 02 Application Guide for additional information)Altronix Corp.140 58th St. Brooklyn, NY

Page 2 - Specifications:

- 10 - AL602ULADAAppendix A - UL Listed Compatible DevicesA.1 Four (4) Wire Smoke DetectorsTableA-1belowlistsfour(4)wiresmokedetectorscomp

Page 3 - Installation Instructions:

AL602ULADA - 11 -A.1 Four (4) Wire Smoke Detectors (cont.)Smoke Detector/BaseDetector TypeMax StandbyCurrent (mA)AlarmCurrent (mA)SystemSensor4W

Page 4 - (AL800LGK9E Board)

- 12 - AL602ULADAA.4 StrobesTableA-4belowlistsstrobescompatiblewithAL602ULADANACoutput.Wheelock Devices:Sychronizing HornsAH-12 AH-12WP

Page 5 - AL800LGK9E Logic Board

AL602ULADA - 13 -A.4 Strobes (cont.)Wheelock Devices:Coded Audible AppliancesAMT-12/24AMT-12/24-NYCCH70CSX10-24-DCMT-12/24AMT4-12/24AMT4-1

Page 6 - - 6 - AL602ULADA

- 14 - AL602ULADAA.4 Strobes (cont.)Amseco Devices:ModelsH24RH24WHP-25TMH12/24MH-120RSD24-153075RSD24W75110SAD-24-153075SAD2475110SCM24C-177SCM24W

Page 7 - Hookup Diagram:

AL602ULADA - 15 -Notes:

Page 8 - Maintenance:

- 16 - AL602ULADAEnclosure Dimensions:15.5”x12”x4.5”(393.7mmx304.8mmx114.3mm)Altronixisnotresponsibleforanytypographicalerrors.140

Page 9 - Battery Calculation Worksheet

- 2 - AL602ULADA Agency Listings:• ULListedControlUnitsandAccessoriesfor FireSystems(UL864).• MEA-NYCDepartmentofBuildingsAp

Page 10 - - 10 - AL602ULADA

AL602ULADA - 3 -Power Supply Specifications:AC Input:120VAC60Hz,4amp.Output:Four(4)regulatedsupervisedNACoutputcircuits,24VDC,2.5ampma

Page 11 - AL602ULADA - 11

- 4 - AL602ULADA Note:The2-wirehorn/strobesyncmodewillonlysynchronizehorns,horn/strobes,strobeswith synchronizationcapability.7.

Page 12 - - 12 - AL602ULADA

*Note:TheAL602ULADAwillonlysynchronizehorns,horn/strobesandstrobesthatcontainsynchronizationcapability.Contactsignalmanufacturerfor

Page 13 - AL602ULADA - 13

- 6 - AL602ULADATerminal Identification Table:AL600ADA Power Supply Board*TerminalLegend Function/DescriptionL,G,N Connect120VACtotheseterm

Page 14 - Faraday Devices:

AL602ULADA - 7 -This connection is used tomonitor AC and Bat Fail andwill cause a simultaneous trouble condition to the FACP's IN1 and IN2Comm

Page 15 - AL602ULADA - 15

- 8 - AL602ULADAOptional hookups:1- BatteryandACmonitoring:ACorBatteryFailconditionwillcausethecommontroubleinput[C“FAULT”NC]to

Page 16 - Enclosure Dimensions:

AL602ULADA - 9 -Battery Calculation WorksheetUnitsarecapableofrecharging40AHbatterymax.Iftotalampere-hourrequiredexceeds40AH,decreas