Altronix Maximal3RD Data Sheet Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Accessoires pour les appareils électriques Altronix Maximal3RD Data Sheet. Altronix Maximal3RD Data Sheet User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Maximal3RD rack mount access power controller distributes and switches
power to access control systems and accessories. It converts a 115VAC 50/60Hz
input into sixteen (16) independently controlled 12VDC or 24VDC PTC pro-
tected outputs. Outputs are activated by an normally open (NO) or normally
closed (NC) dry trigger input from an Access Control System, Card Reader,
Keypad, Push Button, PIR, etc. This unit will route power to a variety of access
control hardware devices including: Mag Locks, Electric Strikes, Magnetic
Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure
modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or
may be used to trigger other auxiliary devices. The fire alarm disconnect feature
is individually selectable for any or all of the outputs.
Input:
• 115VAC60Hz.,1.9amp.
• Normallyclosed[NC]ornormallyopen[NO]
dry contact inputs (switch selectable).
Outputs:
• 12VDCor24VDC@6amptotaloutputcurrent.
• Sixteen(16)PTCprotectedoutputs.
• MaximumcurrentperACM8R-Moutputis2amp.
• IndividuallyselectableMagLock/Strike(Fail-Safe,
Fail-Secure) solid state fuse protected outputs.
• Thermalandshortcircuitprotectionwithautoreset.
Fire Alarm Interface:
• LatchingorNon-Latchingfirealarmresetswitch
individually selectable for each output.
• RemoteresetcapabilityforlatchingFireAlarm
Interface mode.
• FireAlarmdisconnectinputoptions:
a) Normallyopen[NO]ornormallyclosed[NC]
dry contact input.
b) Polarity reversal input from FACP signaling
circuit.
Visual Indicators:
• IndividualOutputStatusLEDslocatedonthe
front panel.
Battery Backup:
• Built-inchargerforsealedleadacidorgeltype
batteries (if batteries are required install
separate enclosure).
• Maximumchargecurrent0.7amp.
• Automaticswitchovertostand-bybattery
when AC fails.
• Zerovoltagedropwhenunitswitchesovertobattery
backup (AC failure condition).
Supervision:
• ACfailsupervision(form“C”contact).
• Lowbatteryandbatterypresencesupervision
(form“C”contact).
Additional Features:
• Removableterminalblockswithlockingscrewflange.
• 3-wirelinecord.
• Illuminatedmasterpowerdisconnectcircuitbreaker
with manual reset.
Mechanical:
• Dimensions(HxWxD)(approx.):3.25”(82.55mm)x
19.125”(485.78mm)x8.5”(215.9mm)
• Shipping Weight (approximate):12.7lbs(5.76kg).
Maximal3RD
Rack Mount Access Power Controller
Rev. DSMaximal3RD - 11012012
Overview
Specifications
Maximal3RD
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Maximal3RD

Maximal3RD rack mount access power controller distributes and switches power to access control systems and accessories. It converts a 115VAC 50/60Hz i

Page 2 - TOP & BOTTOM

Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.comFRONTTOP & BOTTOMREARMaximal3RD Rack Chassis Dime

Commentaires sur ces manuels

Pas de commentaire